FACTS & Power Quality

Hyosung’s FACTS (Flexible AC Transmission System) & Power Quality Solution is a uniquely differentiated system that maximizes voltage stability and transmission efficiency and prevents deterioration of power quality.

Search
Hyosung’s FACTS (Flexible AC Transmission System) & Power Quality Solution offers a new solution to solve problems pertaining to the electric power system. The semiconductor switching device that overcomes the limitations of conventional mechanical control devices allows for the reduction of reactive power and ensures enhanced stability against accidents.

Our Offerings

Hyosung’s FACTS (Flexible AC Transmission System) solution supplies leading/lagging reactive power to transmission lines in order to maximize voltage stability and transmission efficiency.
The Power Quality Solution prevents and minimizes the loss of power quality. It performs various functions such as the power supply solution, harmonics solution, voltage solution, and power quality monitoring.
Based on 35 years of accumulated T&D technology, Hyosung provides the best engineering solutions in the areas of FACTS & Power Quality, such as power system analysis, design & construction of substations, and customer service.

Major References

View
  • ±100(200)MVA STATCOM Installed at 345kV Substation
  • ±10(20)MVA STATCOM Supplied to Distribution Grid
  • 80MVA UPFC Installed at Substation

Related Products

Sitemap Legal Notice Privacy Policy
COPYRIGHT © 2006 HYOSUNG. ALL RIGHTS RESERVED.
family site

Major Reference

layerClose

±100(200)MVA STATCOM Installed at 345kV Substation

  • Client : Korea Electric Power Company (KEPCO)
  • Site Location : South Korea
  • Product : ±100(200)MVA STATCOM
  • Delivery : 2009
±100(200)MVA STATCOM was installed at the 345kV Migum substation owned by the Korea Electric Power Company (KEPCO) on August 2009 and has been contributing to greater power stability of the transmission grid. ±100(200)MVA STATCOM eases the power circuit alternation and utilized the improved 3-level pole inverter in order to solidify the arrangement. The pole structure was designed as a module form. it is operating with an availability of 99.49%. Each pole has a 4 IGCT value and each IGCT valve is composed of a series of 8 connected IGCTs.
Pulse Number: 24
No. of Pole: 6
No. of Modules per Valve: 8
Nominal DC Bus Voltage (± to mid point): 10,000
Nominal Pole Output Voltage V (ph-n) rms: 8,926

±10(20)MVA STATCOM Supplied to Distribution Grid

  • Site Location : South Korea
  • Product : ±10(20)MVA STATCOM
  • Delivery : 2007
±10(20)MVA STATCOM was installed with a goal of preventing voltage fluctuations and improving power quality for Hyosung Changwon Plant’s 22.9kV distribution grid on March 2007. In 2008, it was operating with an availability of 98.07%.
Inverter rating: ±10(20)MVA
Pulse number: 24
No. of poles: 6
No. of modules per valve: 1
Nominal DC bus voltage: 2,000
Nominal Pole Output Voltage V (ph-n) rms: 1,786

80MVA UPFC Installed at Substation

  • Client : Gangjin Substation
  • Site Location : South Korea
  • Product : 154kV 80MVA UPFC
UPFC is one of FACTS devices using high-capacity voltage source inverter. UPFC controls the power flow by connecting 2 inverters to a power transmission line in serial / parallel manner.
- Through technical alliance with Siemens of USA, 154kV / 80MVA, UPFC was installed in the Gangjin substation and now in operation, for the first time in Korea.
-Connected to 154kV and 345kV high-voltage power transmission system using GTO Thyristor element.
-Independent control of active power, reactive power and terminal voltage of transmission line where UPFC is connected can increase power transmission capacity through maximum use of existing transmission lines.
- Speedy compensation function realized by swift control time in an accident or overload status, which is not available in the existing phase modifying equipment, contributes to the stabilization of a power transmission system.
-Modularized GTO valve enables easy maintenance

±1(2)MVA STATCOM

  • Client : Gaya Substation
  • Site Location : South Korea
  • Product : ±1(2)MVA STATCOM
  • Delivery : 1999
Through technical alliance with Siemens of USA, 22.9kV / ±1(2)MVA, DSTATCOM was installed in a Haman substation and is now in operation, for the first time in Korea.
Key functions
-Mitigation of voltage flicker
-Compensation for change in load-end voltage and harmonics
-Improvement of power factor
Effect from installation
-Preventing influence of malignant load in factory on neighbor around distribution system.
-Improved utilization of lines
-Stabilized power supply and improved system efficiency